bims-metlip Biomed News
on Methods and protocols in metabolomics and lipidomics
Issue of 2026–11–08
fifty-four papers selected by
Sofia Costa, Matterworks



  1. Methods Mol Biol. 2027 ;3095 13-26
      This chapter describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of drugs of abuse and their metabolites in human urine. The target analytes include 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC-COOH), benzoylecgonine, 6-acetylmorphine, morphine, codeine, 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), amphetamine, and methamphetamine. Sample preparation involves enzymatic hydrolysis with β-glucuronidase, followed by dilution with methanol and centrifugation, enabling direct analysis without derivatization. Chromatographic separation is achieved within 4 min, and detection is performed in multiple reaction monitoring mode with deuterated internal standards for reliable quantification. This simple and robust approach fulfills international requirements for confirmatory urine drug testing and can be readily implemented in forensic and workplace toxicology laboratories.
    Keywords:  Drugs of abuse; Forensic toxicology; UHPLC–MS/MS; Urine
    DOI:  https://doi.org/10.1007/978-1-0716-5651-8_2
  2. bioRxiv. 2026 Oct 26. pii: 2026.10.21.760801. [Epub ahead of print]
      Integrating ion mobility spectrometry (IMS) with liquid chromatography-mass spectrometry (LC-MS) has the potential to improve untargeted metabolomics workflows, but assessing the benefits of IMS has been challenging due to a paucity of software solutions to process raw LC-IMS-MS data in a manner that enables direct comparison with LC-MS data. We developed the XCiMS software to collapse 4D data into pseudo-3D data. Peak detection is then performed in the pseudo-3D space, followed by targeted extraction of 4D signals from 3D-guided regions of interest. Here, we applied XCiMS to estimate the potential of IMS for untargeted metabolomics when analyzing human plasma. First, we assessed the number of metabolites that are uniquely resolved by LC-IMS-MS but not LC-MS. Although as many as 50% of 3D peaks produce multiple 4D peaks when using high-resolution IMS, few represent newly resolved structural isomers. We found that the increase in features due to IMS was mostly caused by charge isomers and ion clusters. Second, we investigated the impact of IMS on metabolite identification. When using a 16-minute chromatographic separation, we found that IMS can decrease the frequency of chimeric MS/MS by about half. We conclude that while IMS adds considerable complexity to untargeted metabolomics data without resolving a large number of additional structural isomers relative to a standard LC-MS experiment, it does facilitate metabolite identification by decreasing chimeric spectra and providing CCS values for library searching.
    DOI:  https://doi.org/10.64898/2026.10.21.760801
  3. Methods Mol Biol. 2027 ;3095 161-176
      Tryptamines constitute a class of organic compounds structurally derived from tryptamine, a natural alkaloid found in plants, fungi, and the human body. This group encompasses biologically significant molecules such as serotonin and melatonin, as well as psychoactive compounds like DMT and psilocybin. Tryptamines are typically classified into simple tryptamines and ergolines, with further subclassifications based on structural modifications on the indole ring system. Their primary mechanism of action involves modulation of serotonergic receptors, especially the 5-HT2A, often resulting in psychedelic effects. While some tryptamines are naturally occurring, others are synthetically produced and increasingly encountered as new psychoactive substances. The study presents a rapid and robust LC-MS/MS method for the simultaneous detection and quantification of 37 tryptamines in human urine and plasma. The method employs a ThermoFisher UHPLC-LC-MS/MS system using a Hypersil GOLD C18 column and gradient elution, with MS^n acquisition in positive ESI mode. Analytical validation demonstrated high selectivity, sensitivity, and reproducibility. Sample preparation was performed through a combination of liquid-liquid and protein precipitation extraction procedures. The method successfully identified tryptamines using product ion spectra compared to a reference spectral library, with detection limits, recovery, and matrix effects systematically evaluated. This analytical approach provides a reliable tool for forensic and clinical toxicology, particularly in the context of the increasing interest in tryptamines for both recreational and therapeutic purposes.
    Keywords:  Analytic sample preparation methods; Hallucinogens; Liquid chromatography-mass spectrometry; Plasma; Toxicology; Tryptamines; Urine
    DOI:  https://doi.org/10.1007/978-1-0716-5651-8_14
  4. Bioanalysis. 2026 Nov 03. 1-14
       AIMS: Flualprazolam is a novel designer benzodiazepine frequently reported in drug-facilitated sexual assaults, yet validated methods for its quantification in human seminal fluid remain limited. A sensitive method was therefore developed and validated for quantification of flualprazolam and α-hydroxy flualprazolam in human seminal fluid.
    MATERIALS AND METHODS: An ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed using solid-phase extraction, a phenyl-hexyl reversed-phase column, positive electrospray ionization and multiple reaction monitoring. Results: The method showed linearity over 0.5-200 ng/mL (R2 ≥ 0.99). Limits of detection (LOD) and lower limits of quantification (LLOQ) were 0.250 and 0.500 ng/mL, respectively. Accuracy and precision were within ±20%, with extraction recovery >81%. The method was applied to 100 seminal-fluid samples.
    CONCLUSIONS: The validated method enables sensitive quantification of flualprazolam and α-hydroxy flualprazolam in human seminal fluid for forensic toxicological applications.
    Keywords:  Drug abuse; UHPLC-MS/MS; designer benzodiazepines; flualprazolam; method development and validation; seminal fluid
    DOI:  https://doi.org/10.1080/17576180.2026.2758060
  5. J Chromatogr B Analyt Technol Biomed Life Sci. 2026 Nov 03. pii: S1570-0232(26)00444-7. [Epub ahead of print]1286 125355
      Tryptophan-derived indole-3 metabolites are increasingly recognized for their role as central mediators in health and disease by regulating systemic metabolism and immunity. Hence, there is a growing interest in methods that enable robust and accurate quantification of this family of metabolites. Therefore, we developed a new bioanalytical assay, using FDA and EMA guidelines, to quantify these metabolites in human plasma using stable isotope labeled internal standards and liquid chromatography coupled to a triple quadrupole mass spectrometric detector. After protein precipitation with acetonitrile and separation on a short reversed-phase column in gradient mode, compounds were quantified in positive selected reaction monitoring mode of an electrospray source. Responses were linear for indole-3-propionic acid (5-2000 ng/ml) and DL-indole-3-lactic acid (10-4000 ng/ml), whereas a quadratic least-squares regression model was used for indole-3-acetic acid (10-4000 ng/ml) and indole-3-carboxaldehyde (2.5-1000 ng/ml). Precisions in human plasma, within- and between-run, were within 2.4-12.1%, accuracies ranged from 89.1 to 107.7%. Indoles were all stable under all investigated conditions, including repeated freeze-thaw cycles. Significant extraction losses or matrix effects were not observed. Overall, the method provides a relatively fast and simple bioanalytical assay suitable for quantification of indoles in clinical setting.
    Keywords:  Indole-3-acetic acid; Indole-3-carboxaldehyde; Indole-3-lactic acid; Indole-3-propionic acid; LC-MS/MS; Plasma; Selected reaction monitoring
    DOI:  https://doi.org/10.1016/j.jchromb.2026.125355
  6. Methods Mol Biol. 2027 ;3095 81-94
      Oral fluid is an increasingly valuable biological matrix in Forensic and Clinical Toxicology due to its advantages over blood and urine, such as non-invasive and directly supervised sample collection, minimal risk of adulteration, and its ability to reflect recent drug intake. Consequently, oral fluid is now widely employed in various applications such as anti-doping control, therapeutic drug monitoring, and, most notably, workplace drug monitoring and roadside drug testing. This chapter describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the confirmatory analysis of 21 illicit and licit drugs in oral fluid. The protocol includes detailed procedures for sample conditioning, clean-up by solid-phase extraction (SPE) and LC-MS/MS analysis. The method enables the simultaneous quantification of major drug classes, including cannabis, cocaine, opioids, amphetamines, benzodiazepines, and other psychoactive substances, with a limit of quantification (LOQ) of 1 ng/mL for all analytes.
    Keywords:  Driving under the influence; Drugs of abuse; LC–MS/MS; Mass spectrometry; Oral fluid; Psychoactive medications; Solid-phase extraction; Workplace drug monitoring
    DOI:  https://doi.org/10.1007/978-1-0716-5651-8_7
  7. J Am Soc Mass Spectrom. 2026 Nov 04. 37(11): 2873-2882
      Metal-sensitive metabolites frequently exhibit poor chromatographic performance during liquid chromatography-mass spectrometry (LC-MS) due to analyte interactions with stainless-steel components of the chromatographic system. Although mobile phase chelators are widely used to improve targeted analyses, their broader effects on untargeted metabolomics remain unclear. We systematically evaluated the impact of chromatographic chelator modifiers on untargeted LC-MS detection of Pseudomonas aeruginosa secondary metabolites using the metal-chelating quorum-sensing molecule Pseudomonas Quinolone Signal (PQS) as a model analyte. Analysis of publicly available metabolomics data sets revealed substantial variability in PQS chromatographic performance across laboratories. From this observation, we hypothesized that metal-mediated adsorption may contribute to inconsistent detection of PQS. We compared the effects of EDTA and citrate as mobile phase additives on P. aeruginosa metabolite detection across multiple culture media. Both chelators markedly improved PQS peak shape and enhanced detection of PQS and the siderophore pyochelin. However, high concentrations of EDTA caused ion suppression, altered adduct formation, and reduced detection of several metabolite classes, including phenazines and rhamnolipids, while citrate eliminated detection of phenazine-1-carboxylic acid (PCA). Reducing EDTA concentration to low micromolar levels largely preserved chromatographic improvements while minimizing adverse effects on metabolite coverage, although suppression of PCA persisted. These trends were consistent across chemically distinct growth media. Collectively, our findings demonstrate that mobile phase chelators substantially influence untargeted metabolomic profiles beyond improving chromatography. Careful selection of chelator identity and concentration is therefore essential to balance chromatographic performance with comprehensive metabolite detection in untargeted LC-MS analyses of metal-sensitive metabolites.
    DOI:  https://doi.org/10.1021/jasms.6c00299
  8. Curr Protoc. 2026 Nov;pii: e70470. [Epub ahead of print]6(11):
      Metabolomics enables the profiling of small-molecule metabolites, thereby capturing the biochemical state of a living organism at a given moment and making it possible to monitor the organism's cellular responses to stimuli. This technique has become a powerful tool in pharmaceutical research, the food industry, and microbial research. Metabolomics aims to obtain an unbiased metabolic profile; however, this is complicated by compound instability, the requirement for complex and often extensive sample processing, and nonlinear responses in mass spectrometry. Therefore, correcting for metabolite loss and mass-spectrometry-related artifacts is essential; this is typically achieved through relative quantification against an isotopically labeled internal standard for each metabolite of interest. This article describes a method to produce 13C-labeled yeast extract and its use as internal standard for metabolomics. More specifically, it provides step-by-step protocols for the fed-batch fermentation, quenching, metabolite extraction, and LC-MS and GC-MS characterization of the internal standard. It also includes a protocol explaining how to use the internal standard for the quantification of metabolites in yeast samples. © 2026 The Author(s). Current Protocols published by Wiley Periodicals LLC. Basic Protocol 1: Trial run-fed-batch fermentation Support Protocol 1: Dry weight determination Basic Protocol 2: Quenching and washing of the cell samples and metabolite extraction Basic Protocol 3: Identification of intracellular metabolites using LC-MS Basic Protocol 4: Identification of intracellular metabolites using GC-MS Basic Protocol 5: Real run-fed-batch fermentation Basic Protocol 6: LC-MS characterization of the internal standard Basic Protocol 7: GC-MS characterization of the internal standard Basic Protocol 8: Quantification of metabolites in yeast samples.
    Keywords:  13C‐labeled yeast extract; Fed‐batch fermentation; Internal standards; Mass spectrometry; Metabolomics
    DOI:  https://doi.org/10.1002/cpz1.70470
  9. Bioanalysis. 2026 Nov 05. 1-8
       PURPOSE: Pancreatic ductal adenocarcinoma (PDAC) remains a highly lethal malignancy, with KRASG12D mutations present in approximately 40-45% of cases. Emerging RAS(ON) inhibitors, including RMC-6236, RMC-9805, RMC-7977, and MRTX1133, offer a promising precision medicine alternative to nonspecific chemotherapy. However, except for MRTX1133, published methods for quantifying these compounds in human plasma or blood remain unavailable.
    METHODS: We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of RMC-6236, RMC-9805, RMC-7977, and MRTX1133 in human plasma. Plasma proteins were precipitated with ethanol using reserpine, verapamil, and labetalol as internal standards. Before LC-MS/MS analysis, 4,4'-methylenebis(2,6-diethylaniline) was added as a volumetric standard. Volumetric and internal-standard quantification produced comparable results. Due to matrix effects, analytes should be quantified using calibration curves prepared in spiked plasma.
    RESULTS: The method showed excellent linearity, with r2 > 0.991, across 0.1-50 ng per 0.1 mL plasma. The lower limit of quantification from spiked plasma (0.1 mL) was 0.1 ng for RMC-6236, RMC-9805, and RMC-7977, and 0.02 ng for MRTX1133.
    CONCLUSIONS: This first simultaneous assay for multiple KRASG12D inhibitors in human plasma supports pharmacokinetic studies and biomarker-driven PDAC clinical trials.
    Keywords:  KRASG12D; LC–MS/MS; PDAC; RMC-6236; RMC-7977; RMC-9805
    DOI:  https://doi.org/10.1080/17576180.2026.2758539
  10. J Mass Spectrom. 2026 ;pii: e70130. [Epub ahead of print]61(11):
      Free amino acids in human saliva are increasingly recognized as valuable biomarkers for noninvasive health monitoring and disease diagnosis owing to their close association with systemic metabolic status. However, their accurate quantification remains challenging because of low physiological concentrations and high matrix complexity. In this study, a robust method based on hydrophilic interaction liquid chromatography coupled with Orbitrap high-resolution mass spectrometry (HILIC-Orbitrap HRMS) was developed for the simultaneous quantification of 20 amino acids in human saliva. Chromatographic separation was achieved using a BEH Amide column (150 mm × 2.1 mm, 1.7 μm) with a gradient elution program. Mass spectrometric detection was performed in positive-ion mode using a Full MS plus scheduled parallel reaction monitoring (PRM) acquisition scheme (hereafter referred to as PRM). The method exhibited excellent linearity (R2 > 0.991), accuracy (80.01%-119.60%), and precision (RSD < 10%). The limits of detection and quantification were 0.030-0.100 and 0.125-0.500 μmol/L, respectively. In addition, data-independent acquisition (DIA) was used to screen for co-eluting isobaric interferences; potential interferents such as 5-aminovaleric acid (for valine) and N,N-dimethylglycine (for 4-aminobutyric acid) were flagged and subsequently resolved with authentic standards. This validated HILIC-HRMS method provides a reliable platform for targeted quantification of polar amino acids in saliva, with DIA serving as a complementary tool for interference screening to ensure analytical specificity.
    Keywords:  DIA; HILIC‐Orbitrap HRMS; PRM; amino acid; human saliva
    DOI:  https://doi.org/10.1002/jms.70130
  11. Anal Chem. 2026 Nov 03. 98(43): 29937-29946
      High-resolution LC-MS-based metabolomics requires transforming noise-dominated raw data into quantitative feature tables and, ultimately, biologically meaningful insights. In practice, this process is fragmented across multiple tools and involves extensive parameter tuning and manual curation. Emzing is a web-based, vendor-agnostic platform that integrates end-to-end analysis, from raw data interrogation to statistical interpretation, within a unified environment. Emzing introduces data-driven, deep learning-based methods for signal extraction and feature quantification, formulating peak detection as a supervised learning problem in both spectral and chromatographic domains. A data-driven noise estimation strategy replaces fixed intensity thresholds, improving sensitivity to low-intensity signals. Feature correspondence across samples is established using robust retention-time alignment and graph-based grouping, while correlation-driven feature tagging assigns isotopes, adducts, and in-source fragments. Metabolite annotation (MSI level 2) combines spectral denoising with composite scoring of MS/MS spectra against reference libraries. Emzing further integrates processing with downstream statistical and machine learning-based analyses to facilitate reliable biological interpretation. Interactive visualization across all stages enables transparent curation and rapid iteration from initial results to publication-quality outputs. The use of pretrained models in inference mode, together with a reduced parameter space, supports reproducible analysis. Emzing improves true-feature recovery, quantitation accuracy, and reproducibility on benchmark data sets while reducing reliance on manual intervention. Scalability is demonstrated through Emzing Vault, a repository containing over 110 reprocessed public domain data sets.
    DOI:  https://doi.org/10.1021/acs.analchem.6c02696
  12. J Am Soc Mass Spectrom. 2026 Nov 04. 37(11): 2742-2748
      Electrospray ionization mass spectrometry (ESI-MS) is a standard and robust technique for analysis of a large variety of biomolecules. Direct infusion approaches offer rapid, high-throughput analysis of small sample volumes but are inherently susceptible to matrix effects during electrospray ionization. These matrix effects can substantially alter analyte ionization and gas-phase response and thereby complicate the interpretation of analyte abundances in complex biological samples. Herein, we developed a titration-based workflow to identify matrix effects and distinguish true changes in endogenous analyte abundance from ionization artifacts using direct infusion probe mass spectrometry (DIP-MS). Rat brain tissue extracts, rat insulinoma cell extracts, and isotopically labeled internal standards were used to model different matrix complexities to define condition-based differences in matrix effects. Thereafter, by mixing paired extracts in different ratios and fitting linear regression models, we assessed analyte-specific responses to sample-specific matrices. Moreover, we uncovered ion suppression or enhancement of hundreds of analytes by comparing regression slopes using interaction tests. We find that using endogenous analytes in our titration-based workflow gives a good indication of matrix effects for certain analyte classes. However, using a preselected panel of internal standards is strongly favorable for reliably identifying matrix effects during ionization. Altogether, combining our titration workflow, a selected panel of internal standards, and regression modeling provides a sensitive way of detecting matrix effects and for distinguishing true metabolite abundance changes from ionization artifacts.
    DOI:  https://doi.org/10.1021/jasms.6c00220
  13. J Sep Sci. 2026 Nov;pii: e70572. [Epub ahead of print]49(11):
      A novel effervescent tablet based on zeolitic imidazolate framework (ZIF)-67-derived nanoporous carbon was fabricated and applied for simultaneous analysis of clozapine (CPZ) and its metabolites in human urine samples coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Adsorption experiments and X-ray photoelectron spectroscopy analysis revealed the affinity of ZIF-67-derived nanoporous carbon toward the analytes through π-π, hydrophobic, hydrogen bonding, and coordination interactions. Meanwhile, this sorbent exhibited excellent exclusion ability against interfering substances in urine samples. For the construction of the ZIF-67-derived nanoporous carbon-based effervescent tablet, both the tablet composition and the parameters affecting magnetic solid-phase extraction were optimized in detail. The proposed magnetic effervescent tablet enabled a fast adsorption process (∼5 min) and provided enhanced extraction efficiency (87.4%-98.3%) in a simple and convenient step. Coupled with LC-MS/MS, the developed method offered acceptable matrix effects of 0.98-1.00, wide linear ranges of 0.06-3000 ng/mL with correlation coefficients ≥0.9990, low detection limits of 0.02-0.30 ng/mL, and satisfactory recoveries of 91.1%-99.2%. In addition, the present approach allowed direct loading of crude urine samples without additional dilution and filtration steps, significantly simplifying the operation procedure. These results demonstrated an alternative strategy for highly efficient and convenient monitoring of CPZ and its metabolites in urine samples and proved the great application potential of ZIF-67-derived nanoporous carbon effervescent tablets for extracting pharmaceuticals from complex samples.
    Keywords:  LC‐MS/MS; MOF‐derived porous carbon; clozapine; effervescent tablet‐assisted solid phase extraction; urine
    DOI:  https://doi.org/10.1002/jssc.70572
  14. J Am Soc Mass Spectrom. 2026 Nov 04. 37(11): 2731-2741
      Untargeted liquid chromatography-high-resolution mass spectrometry (LC-HRMS) supports high-throughput metabolomics, but rapid gradients can compress chromatographic separation and limit downstream annotation. A practical annotation strategy is to analyze all samples using a rapid untargeted method and then reinject selected biological and pooled quality-control (QC) samples under a longer-gradient method to improve separation, MS/MS acquisition, and standard-based confirmation. Because short- and long-gradient feature tables cannot be matched reliably by m/z alone, we developed RTBridge, a same-sample, feature-table-based retention-time (RT) bridging workflow that establishes feature correspondence without requiring structural descriptors or quantitative structure-retention relationship models. Unique anchors were selected using within-method mass uniqueness, cross-method mass agreement, and an abundance-concordance score (ACS). Six empirical RT-transfer models were evaluated: linear regression, piecewise linear interpolation, locally estimated scatterplot smoothing (LOESS), piecewise cubic Hermite interpolation (PCHIP), spline/generalized additive modeling (GAM), and monotone GAM. Using all selected mode-specific anchors, PCHIP produced 5,595 primary feature pairs across four matrix/mode data sets, with a mean median RT error of 0.0232 min. GAM-based residual screening reduced the number of selected training anchors from 1,518 to 1,185, primary-pair recovery from 5,595 to 4,867, and verification support from 161 to 151, while decreasing the mean median RT error to 0.0212 min. We therefore recommend PCHIP RT transfer using all selected mode-specific anchors without residual-based hard deletion, followed by abundance-concordance ranking. RTBridge establishes feature correspondence rather than metabolite identification. Potential extensions include platform or column transfer, batch harmonization, cross-matrix correspondence, and interlaboratory integration but will require direct experimental validation.
    Keywords:  LC-HRMS; abundance concordance; cross-gradient bridging; retention-time transfer; untargeted metabolomics
    DOI:  https://doi.org/10.1021/jasms.6c00226
  15. Methods Mol Biol. 2027 ;3095 113-123
      This chapter presents a sensitive and efficient method for the determination of ketamine, its primary metabolites (norketamine and 6-hydroxynorketamine), and its analogs 2-fluorodeschloroketamine (2F-DCK) and deschloroketamine (DCK) in urine samples. The procedure is based on dispersive liquid-liquid microextraction (DLLME) followed by LC-MS/MS detection, offering several advantages aligned with Green Analytical Toxicology principles, such as reduced solvent consumption, low sample volume, and short processing time. The method demonstrated good linearity and sensitivity and was successfully applied to authentic urine samples as a proof of concept, confirming its suitability for forensic and clinical toxicological investigations.
    Keywords:  Dispersive liquid–liquid microextraction; Ketamine; LC–MS/MS; New psychoactive substances; Urine
    DOI:  https://doi.org/10.1007/978-1-0716-5651-8_10
  16. Methods Mol Biol. 2027 ;3095 133-145
      The rapid emergence of Novel Psychoactive Substances (NPS) poses challenges for forensic toxicology laboratories. Hair offers a unique matrix for retrospective drug exposure monitoring due to its long detection window, noninvasive collection, and high stability. Here, we describe a fast, high-throughput method for the detection and quantitation of over 30 emerging NPS from multiple drug classes, including synthetic opioids, cathinones, cannabinoids, dissociative drugs, designer benzodiazepines, and hallucinogens, in human hair using liquid chromatography-tandem mass spectrometry (LC-MS/MS). This procedure uses bead mill pulverization, methanolic extraction, and LC-MS/MS analysis with a multianalyte calibration curve.
    Keywords:  Human hair; Human monitoring; Mass spectrometry; Multianalyte; NPS
    DOI:  https://doi.org/10.1007/978-1-0716-5651-8_12
  17. Methods Mol Biol. 2027 ;3095 55-79
      Synthetic cannabinoids (SCs) remain a prominent and dynamic class of new psychoactive substances (NPS), frequently encountered in forensic toxicology casework. Their extensive metabolism, low concentrations in biological matrices, and continual emergence of new analogues demand analytical strategies that are both sensitive and adaptable. The present work describes streamlined and sensitive workflows for the identification of SCs and their metabolites in urine and hair using LC-MS-based screening and confirmation approaches. Enzymatic hydrolysis, clean-up using supported liquid extraction or solid-phase extraction, and hair pulverization enable efficient recovery, while data-dependent acquisition and defined identification criteria ensure reliable qualitative findings. The sample preparation procedures, analytical parameters, and identification criteria are fully presented.
    Keywords:  Hair; New psychoactive substances; Solid-phase extraction; Solid–liquid extraction; Synthetic cannabinoids; Urine
    DOI:  https://doi.org/10.1007/978-1-0716-5651-8_6
  18. Methods Mol Biol. 2027 ;3095 35-40
      This study describes a method for the analysis of cocaine, its metabolites, and opioids in whole blood samples using protein precipitation, followed by detection with liquid chromatography-tandem mass spectrometry (LC-MS/MS). This method utilizes low sample volumes (0.1 mL) and minimizes matrix effects for enhanced sensitivity and reproducibility. Samples are prepared straightforwardly, ensuring a reliable and fast workflow for forensic toxicological applications.
    Keywords:  Cocaine; LC–MS/MS; Metabolites; Opioids; Protein precipitation; Whole blood
    DOI:  https://doi.org/10.1007/978-1-0716-5651-8_4
  19. Adv Sci (Weinh). 2026 Nov 05. pii: e78657. [Epub ahead of print]
      High-resolution spatial mapping of tissue molecular architecture-from metabolites and lipid isomers to native proteins-remains a central challenge for ambient mass spectrometry imaging (MSI). Existing methods typically rely on multi-capillary, alignment-sensitive liquid-extraction probes, compromising robustness and compatibility with structure-resolved spatial omics. We mitigate this trade-off by introducing a monolithic, knot-shaped open microfluidic probe (Knot-probe) fabricated from a single capillary. Knot-probe achieves 40 µm scan-direction spatial resolution and acquisition throughput up to 0.16 mm s-1, yet can be fabricated in ∼30 min with standard laboratory tools and operated reliably for over one month. Without sacrificing conventional spatial lipidomics and metabolomics, Knot-probe enables structure-resolved spatial omics, delivering high-resolution imaging of phosphatidylcholine sn-positional isomers via tandem MS and, in a pneumatically-assisted variant, native MSI of proteins and proteoforms with higher throughput and enhanced sensitivity than with probes lacking pneumatic assistance. These capabilities arise from the integrated knot geometry, which ensures a stable micro-liquid junction for localized extraction with a minimized sampling footprint and efficient mass transfer, while eliminating intricate probe alignment for robust operation. Readily integrated with standard electrospray ionization MS, Knot-probe bridges conventional ambient MSI and emerging structural spatial omics, offering a broadly accessible approach across diverse biological and chemical applications.
    Keywords:  ambient mass spectrometry; lipid isomer; lipidomics; metabolomics; native mass spectrometry; proteomics; spatial omics
    DOI:  https://doi.org/10.1002/advs.78657
  20. J Sep Sci. 2026 Nov;pii: e70567. [Epub ahead of print]49(11):
      Glyphosate (GLYP) and glufosinate (GLUF) are widely used herbicides that can persist in aquatic environments. Rapid, sensitive, and matrix-versatile analytical methods for the simultaneous monitoring of these herbicides, along with their major metabolites (aminomethylphosphonic acid: AMPA, and 3-(methyl-phosphinico)-propionic acid: MPPA), remain limited. Most existing liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods require derivatization or target only food matrices, with little attention to environmental water and sediment. In this study, we developed a high-throughput, non-derivatization ultra-high-performance LC (UHPLC)-MS/MS method incorporating solid-phase extraction using Oasis PRiME HLB cartridges to directly determine all four analytes in both water and sediment samples. The PRiME HLB cartridge effectively reduces interfering substances (such as salts, organic matter, and phospholipids) without conditioning or elution steps, thereby simplifying sample preparation and enabling high-throughput analysis. The method was validated across six distinct environmental matrices (pond, lake, river water, and corresponding sediments). Excellent linearity (R2 > 0.996), satisfactory recoveries (78.3%-104.7%), precision (RSD < 15%), and sensitivity (limits of detection [LODs]: 0.3-0.5 µg L- 1 for water and 2-3 µg kg- 1 for sediment) were achieved, with negligible matrix effects (<20%). Applied to 60 real environmental samples, the method detected GLYP and AMPA residues in sediments (up to 15.6 and 45.4 µg kg- 1, respectively), while GLUF and MPPA were below LODs. This simple, robust, and high-throughput workflow is well suited for routine monitoring of herbicide residues in aquatic systems.
    Keywords:  environmental analysis; herbicides; residue detection; sample preparation; solid‑phase extraction
    DOI:  https://doi.org/10.1002/jssc.70567
  21. J Sep Sci. 2026 Nov;pii: e70568. [Epub ahead of print]49(11):
      Occupational exposure to softwood dust has been linked to upper and lower respiratory symptoms, eye irritation, contact dermatitis, and an elevated risk of sino-nasal cancer. Resin acids, naturally occurring extractives that vary by tree species, are suspected contributors to these health effects, yet existing analytical methods have struggled to resolve key isomeric acids. This study aimed to develop a rapid, robust, sensitive, and selective liquid chromatography-mass spectrometry (LC-MS) method for the determination of individual resin acids in personal wood dust samples from Norwegian sawmills. Six commercially available reversed-phase columns and multiple mobile phase systems were evaluated for chromatographic performance. Optimal separation was achieved with a C18-amide column (150 × 2.1 mm, 3 µm) using an isocratic mobile phase of acetonitrile and 30 mM ammonium acetate at pH 6.30, 0.3 mL min-1 with a 15-min runtime. Optimal detection employed atmospheric pressure chemical ionization (APCI) in negative mode. This method was applied to six personal sawmill dust extracts, enabling determination of five resin acids (abietic acid, dehydroabietic acid, levopimaric acid, and the coeluting isopimaric and pimaric acids) and one oxidation product (7-oxodehydroabietic acid). The LC-APCI-MS method improves separation of resin acids over prior LC approaches, with minimal sample preparation, and is suitable for routine monitoring of occupational exposure to resin acids in wood dust.
    Keywords:  isomer resolution; occupational exposure; resin acids; wood dust
    DOI:  https://doi.org/10.1002/jssc.70568
  22. Int J Mass Spectrom. 2027 Jan;pii: 117698. [Epub ahead of print]531
      Nanospray desorption electrospray ionization (nano-DESI) is an ambient mass spectrometry imaging (MSI) technique that enables molecular imaging of individual proteoforms in tissue sections. Nano-DESI generates multiply charged ions of intact proteoforms directly from the tissue, which facilitates their identification using on-tissue tandem mass spectrometry (MS/MS) and combined with database searching. We have developed an approach that enables imaging of proteoforms with a spatial resolution of 10 μm. In this chapter, we provide a detailed protocol for high-resolution imaging of proteoforms using nano-DESI MSI.
    Keywords:  Ambient ionization; Biological tissue sections; Mass spectrometry imaging; Nanospray desorption electrospray ionization (nano-DESI); Post-translational modifications (PTMs); Proteins; Proteoforms
    DOI:  https://doi.org/10.1016/j.ijms.2026.117698
  23. J Am Soc Mass Spectrom. 2026 Nov 04. 37(11): 2749-2758
      Waste cooking oil is a potentially renewable substitute for crude oil for the generation of transportation fuels. Unfortunately, compared with the compounds found in crude oil, the compounds in waste cooking oil contain more heteroatoms, such as nitrogen, sulfur, and chlorine. Chlorinated compounds, for example, may arise upon reactions of unsaturated fatty acids, a major component of cooking oil, and hypochlorous acid, which is a frequently used cleaning agent. The goal of this study was to develop a methodology based on tandem mass spectrometry for the detection, identification, and quantitation of chlorinated fatty acids in waste cooking oil. Due to the often low concentrations of chlorine-containing compounds in waste cooking oil samples, the method involved the initial separation of polar compounds, such as fatty acids, from nonpolar compounds, such as glycerides, by using reversed-phase solid-phase extraction (SPE). A reversed-phase high-performance liquid chromatography (HPLC)/negative-ion-mode electrospray ionization (ESI) high-resolution tandem mass spectrometry (HRMS/MS) method was used to identify and quantify the chlorinated fatty acids. Monochloro-, dichloro-, and chlorohydroxy fatty acids were identified in the waste cooking oil samples by determining their elemental compositions via accurate mass measurements and by comparing their HPLC retention times to those of model compounds. Further, the collision-activated dissociation (CAD) patterns of their deprotonated forms were measured using MS/MS experiments and compared to those of deprotonated model compounds, thus acquiring valuable information about the fragmentation behavior of deprotonated chlorinated fatty acids. The accuracy of the quantitation method was determined to be good (greater than 95%) by doping a waste cooking oil sample with a known amount of an internal standard. For all identified chlorinated free fatty acids, a coefficient of variation (a measure of precision) was found to be <10% for the quantitation results.
    DOI:  https://doi.org/10.1021/jasms.6c00231
  24. Biomed Chromatogr. 2026 Dec;pii: e70651. [Epub ahead of print]40(12):
      Quetiapine, a second-generation atypical antipsychotic, has broad indications and considerable variation in daily prescribed doses across different diseases, yet its therapeutic window remains narrow (100-500 ng/mL). In clinical practice, quetiapine is frequently co-administered with other psychotropic drugs. To evaluate the impact of commonly co-administered medications on quetiapine plasma concentrations, we developed and validated a rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the simultaneous quantification of quetiapine and 16 commonly co-administered psychotropic drugs in human plasma. Method validation demonstrated good linearity for all analytes, with precision (CV < 15%), accuracy (85%-115%), and extraction recovery (85%-115%) meeting acceptance criteria. Matrix effects were negligible, and no significant carryover or interference was observed. Results revealed complex polypharmacy regimens within the cohort, with up to six psychotropic drugs co-administered with quetiapine. Among the 16 subjects, 56.2% exhibited subtherapeutic quetiapine concentrations (< 100 ng/mL), more frequent in patients co-administered with alprazolam or mirtazapine. It is therefore speculated that alprazolam, mirtazapine, and related agents may influence quetiapine systemic exposure. Clinically, when co-administered with these agents, quetiapine plasma concentrations should be monitored regularly to ensure efficacy and safety.
    Keywords:  UPLC‐MS/MS; plasma concentration; polypharmacy; quetiapine
    DOI:  https://doi.org/10.1002/bmc.70651
  25. Shokuhin Eiseigaku Zasshi. 2026 ;67(5): 205-213
      A reliable LC-MS/MS method was developed for determining residual isoxaflutole and its primary metabolite, metabolite B (isoxaflutole diketonitrile), in livestock products. Isoxaflutole is an unstable compound that rapidly degrades to its metabolites. To prevent the conversion of isoxaflutole to its metabolites during sample preparation, a mixture of 4 mol/L HCl and ethanol (1 : 1, v/v) was added to the sample in an amount equivalent to half of the sample weight and mixed. Analytes were extracted with acetonitrile in the presence of n-hexane, followed by partitioning with a mixture of ethyl acetate and n-hexane (3 : 7, v/v) and a sodium chloride solution. The organic layer was cleaned up using an Oasis HLB cartridge and then analyzed by LC-MS/MS. Validation was performed through recovery tests using five livestock products. Samples were spiked with isoxaflutole and metabolite B at 0.01 mg/kg and at the maximum residue limits established for each food. The validation results for the analytes showed excellent recoveries (80-94%) and high precision (<10%).
    Keywords:  LC-MS/MS; isoxaflutole; livestock products; metabolite B; prevention of conversion
    DOI:  https://doi.org/10.3358/shokueishi.67.205
  26. Plant Cell. 2026 Nov 05. pii: koag337. [Epub ahead of print]
      Plants are multicellular systems composed of highly specialized cell types, whose distinct transcriptomes, proteomes, and metabolomes collectively shape growth, development, defense, and environmental adaptation. While single-cell transcriptomics has transformed our understanding of plant cellular heterogeneity, metabolites provide a direct and integrative readout of cellular biochemical activity and physiological state and can offer valuable insights into phenotype. They provide essential information that gene expression alone does not capture. Recent advances in mass spectrometry-based single-cell metabolomics (scMet) have enabled direct measurement of metabolic variation across individual cells and subcellular domains. In parallel, mass spectrometry imaging (MSI) has emerged as a powerful approach for mapping the spatial organization of metabolites within intact plant organs, offering new opportunities to connect chemical diversity with anatomy, cell identity, and biological functions. This review summarizes current technologies for plant single-cell sampling, scMet, and MSI for spatial metabolomics. It further highlights emerging efforts to illuminate the plant's cellular and spatial dark metabolome through spectral libraries, computational metabolomics, and AI-assisted annotation. A long-term objective is to build quantitative, spatially resolved, and biologically interpretable plant signaling and metabolic networks at single-cell resolution.
    Keywords:  Single-cell metabolomics; artificial intelligence; dark metabolome; machine learning; mass spectrometry imaging
    DOI:  https://doi.org/10.1093/plcell/koag337
  27. J Proteome Res. 2026 Nov 06. 25(11): 6003-6017
      Comprehensive proteome profiling requires improved depth and throughput, which have traditionally relied on advances in mass spectrometry (MS) and chromatographic separation. Here, we present fracSLIM, a high-throughput, deep-coverage proteomics workflow that integrates structures for lossless ion manipulation (SLIM)-based high-resolution ion mobility spectrometry-mass spectrometry (IMS-MS) with offline peptide fractionation. This approach leverages ion mobility-derived information, including enhanced separation of isomeric and isobaric species and accurate collision cross-section (CCS) measurements, to enable confident peptide identification. We evaluated the utility of this approach for complex proteomics samples by analyzing three fractions of peptide digests from human HeLa cells, enabling an over 10-fold increase in peptide identifications compared to conventional single-shot LC-MS workflows while maintaining high reproducibility. Furthermore, the workflow supports quantitative analysis by comparing endogenous peptides to heavy-isotope-labeled standards. These results highlight the potential of fracSLIM for greatly improved high-throughput and deep proteome profiling of complex samples.
    Keywords:  high throughput; ion mobility spectrometry; mass spectrometry; proteomics; structures for lossless ion manipulations (SLIM)
    DOI:  https://doi.org/10.1021/acs.jproteome.6c00116
  28. J Am Soc Mass Spectrom. 2026 Nov 04. 37(11): 2968-2972
      Functional annotation of microbial genes lags behind the pace of genome sequencing, leaving major gaps in our understanding of microbial metabolism. Combining genetic perturbation with untargeted stable isotope tracing metabolomics provides a powerful strategy for identifying pathway intermediates and elucidating microbial metabolic pathways. To streamline this workflow, we developed IsoPairFinder, a computational tool that prioritizes pathway-intermediate feature pairs by analyzing paired unlabeled (12C) and 13C-labeled metabolomics datasets from genetically perturbed microbes. By consolidating redundant liquid chromatography-mass spectrometry (LC-MS) features and pairing features across unlabeled and labeled samples, IsoPairFinder reduces candidate lists to plausible isotope-paired intermediates for downstream validation. We demonstrate the utility of IsoPairFinder in a case study of uric acid catabolism in Clostridium sporogenes, where it filters redundant features and prioritizes LC-MS feature pairs representing gene-associated pathway intermediates. IsoPairFinder is available as an open-source R package and as a web-based workflow within GNPS2. By integrating differential analysis and isotope-pair detection into a single workflow, IsoPairFinder enables microbiologists to connect metabolomic features with microbial gene function more efficiently, thereby accelerating microbial pathway discovery.
    Keywords:  LC−MS; metabolic pathway discovery; microbial metabolism; stable isotope tracing; untargeted metabolomics
    DOI:  https://doi.org/10.1021/jasms.6c00253
  29. J Am Soc Mass Spectrom. 2026 Nov 04. 37(11): 2922-2930
      Tandem mass spectrometry (MS/MS) spectral matching is increasingly performed at the repository scale, where tools such as MASST enable a query spectrum to be compared against heterogeneous public data. Unlike analogous genomic-based searches, repository-scale MS/MS matching lacks integrated false discovery rate (FDR) reporting, leaving parameter selection entirely to user discretion. Here, we evaluate how acquisition factors and analysis filters jointly affect MS/MS matching using a curated library of 40 metabolites spanning ten chemical classes. In this study, we find that normalized collision energies from 30 to 50% balance sufficient fragmentation against loss of larger diagnostic ions, producing the most structurally informative spectra and yielding the highest proportion of repository matches. Using a fragmentation-based decoy library, we show that six minimum matching peaks achieve <1% FDR across the entire cosine threshold range tested (0.7-1.0), while fewer matching peaks require increasingly stringent cosine thresholds. These findings provide practical, benchmarking guidance for user-provided acquisition and search parameters in MASST searches.
    Keywords:  benchmarking; meta-analysis; metabolomics; spectral matching; tandem mass spectrometry
    DOI:  https://doi.org/10.1021/jasms.6c00332
  30. Curr Protoc. 2026 Nov;pii: e70509. [Epub ahead of print]6(11):
      Released N-linked glycans are frequently stored between enzymatic release, cleanup, and LC-MS analysis, yet storage solvent and freeze-thaw handling are often reported incompletely or omitted. This unit provides a procedure for determining, within a given laboratory and for a given glycan preparation, whether a selected storage condition preserves analytical performance prior to LC-ion mobility-mass spectrometry (LC-IM-MS). The workflow compares matched aliquots prepared from a single cleared glycan stock, using extracted ion chromatogram signal intensity, chromatographic peak shape, visible precipitation, and replicate precision as acceptance criteria, assessed both before and after a controlled freeze-thaw cycle. A worked example comparing 0.1% (v/v) formic acid in water with 50:50 acetonitrile:water is presented to demonstrate the workflow. The aqueous condition retained LC-IM-MS signal after one freeze-thaw cycle, while the acetonitrile-containing condition showed substantial post-thaw signal loss despite acceptable pre-freeze performance. This example illustrates the magnitude of effect that storage solvent can produce and is not presented as a general storage recommendation, since susceptibility is both structure dependent and platform dependent. The protocols are intended for laboratories analyzing released N-linked glycans from glycoproteins or biological samples and can be applied to PGC-, reversed-phase-, or HILIC-based LC-MS workflows, with solvent adjustment performed immediately before injection rather than during long-term storage. © 2026 The Author(s). Current Protocols published by Wiley Periodicals LLC. Basic Protocol 1: Solvent selection and solubility assessment of released N-linked glycans before LC-IM-MS analysis Basic Protocol 2: Freeze-thaw stability evaluation and long-term aqueous storage of released N-linked glycan stocks Support Protocol: Preparation of single-use glycan aliquots and pre-injection quality control.
    Keywords:  LC–IM–MS; N‐linked glycans; freeze–thaw stability; glycomics; sample storage
    DOI:  https://doi.org/10.1002/cpz1.70509
  31. Anal Chem. 2026 Nov 03. 98(43): 29991-30001
      Regiospecific analysis of monoacylglycerols (MAGs) remains challenging because of their low endogenous abundance, the limited availability of regioisomeric standards, and rapid acyl migration between the sn-1 and sn-2 positions during sample handling. Here, we report an UHPLC-HRMS platform integrating chemical stabilization with retention-time prediction for confident profiling of MAG regioisomers in biological samples. Derivatization with 4-pyridineboronic acid (4-PyBA) selectively forms cyclic boronate esters with the glycerol cis-diol moiety, thereby suppressing acyl migration, enhancing electrospray ionization efficiency, and generating characteristic diagnostic ions. To minimize reliance on authentic standards, a three-dimensional quantitative structure-retention relationship (3D-QSRR) model was developed to predict chromatographic retention across structurally diverse MAGs. In parallel, a homologous series of fatty acid 1,2-pentanediol monoesters was synthesized as retention calibrants to correct retention time (RT) drift and improve method robustness. These components were integrated into a targeted parallel reaction monitoring (PRM) workflow supported by an in-house database of 288 annotated sn-1 and sn-2 MAGs. Application of this strategy to serum, brain, colon, and fecal samples from APP/PS1 mice and to serum samples from individuals with Alzheimer's disease (AD) enabled the confident annotation of 118 endogenous MAGs, including 68 MAGs not currently catalogued in major public databases. Collectively, this integrated platform improves structural confidence and analytical robustness and establishes a transferable framework for regioisomer-resolved analysis of labile glycerolipids.
    DOI:  https://doi.org/10.1021/acs.analchem.6c05265
  32. J Chromatogr B Analyt Technol Biomed Life Sci. 2026 Oct 27. pii: S1570-0232(26)00440-X. [Epub ahead of print]1285 125351
      Metabolite identification (MetID) workflows frequently rely on generic UHPLC/ESI-MS methods that provide a compromise between chromatographic separation and analytical throughput. However, these methods may fail to adequately resolve complex mixtures of metabolite isomers, resulting in ambiguous structural assignments and additional method development efforts. Here, we evaluate micro-pillar array columns (μPAC) as a practical strategy to improve isomer separation without changing chromatographic selectivity or developing dedicated LC methods. Using hepatocyte incubations with buspirone and verapamil as model compounds, μPAC/nano-ESI-MS was compared with conventional UHPLC/ESI-MS methods under both standard and extended-gradient conditions. For buspirone, μPAC/nano-ESI-MS substantially improved the separation of oxidative metabolite isomers and enabled detection of 14 out of 15 theoretically possible metabolites with two oxidations. For verapamil glucuronides, μPAC/nano-ESI-MS provided superior chromatographic resolution compared with both conventional UHPLC and a 90-min UHPLC gradient, demonstrating that the observed improvements extend beyond the effect of gradient length alone. In addition, μPAC/nano-ESI-MS produced more than an order-of-magnitude increase in signal response despite a 100-fold lower column load. The combined gains in chromatographic resolution and signal intensity improved confidence in metabolite annotation and facilitated the characterization of complex isomeric metabolite mixtures. These results demonstrate that μPAC/nano-ESI-MS represents a valuable workflow enhancement for metabolite identification studies and can be implemented as a second-pass analysis strategy when conventional UHPLC/ESI-MS methods provide insufficient separation power.
    DOI:  https://doi.org/10.1016/j.jchromb.2026.125351
  33. Cancer Cell Int. 2026 Nov 04. pii: 357. [Epub ahead of print]26(1):
       BACKGROUND: Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) is widely used in metabolomics because it enables high-resolution spatial characterization of molecular distributions directly from tissue. Nevertheless, comprehensive analysis of small, polar metabolites remains difficult due to limited ionization efficiencies and diverse chemical structures. On-tissue chemical derivatization (OTCD) has emerged as an effective strategy to improve ionization efficiency, sensitivity, and selectivity for these analytes.
    METHODS: In this study, we established and systematically optimized an OTCD approach for spatial analysis of carbonyl- and carboxyl-containing metabolites in murine tissues using 4-APEBA in combination with carbodiimide crosslinker EDC. Reagent concentrations, solvent composition, and spray parameters were optimized to achieve reproducible derivatization across multiple tissue types.
    RESULTS: The optimized protocol enabled reproducible and confident detection of carbonyl- and carboxyl-containing metabolites in positive ion mode through the characteristic bromine isotopic signature of 4-APEBA. Application to metastatic liver and lung tissue demonstrated the method's performance in biologically complex environments. Pronounced metabolic heterogeneity correlated with histopathological features in tumor-rich liver sections, and clear tumor-specific localizations were obtained in lung tissue with only small metastatic foci. Metabolic differences between tumor and adjacent healthy regions were consistent with established cancer metabolism pathways, including glycolytic reprogramming.
    CONCLUSION: This study is the first to optimize and investigate sample preparation conditions for mouse tissue application of a reliable OTCD workflow using EDC and 4-APEBA for MALDI-MSI-based spatial metabolomics, with localized OTCD-MSI of melanoma metastases. By utilizing this combination of reagents, carbonyl and carboxyl moiety containing molecules are confidently annotated based on isotopic signatures in positive mode ionization. The application is capable of interrogating metabolic heterogeneity in clinically relevant tumor models and demonstrates its value for future investigations of tumor metabolism.
    Keywords:  MALDI-MSI; Metastasis; On-tissue chemical derivatization; Spatial metabolomics
    DOI:  https://doi.org/10.1186/s12935-026-04494-x
  34. Methods Mol Biol. 2027 ;3095 41-54
      Cannabinoids are the most frequently detected psychoactive substances in forensic toxicology. Their presence in blood is indicative of recent cannabis consumption, which is critical in contexts such as driving under the influence of drugs, workplace drug testing, drug-facilitated crimes, and postmortem investigations. In this chapter, we describe a method for the determination of several cannabinoids and their metabolites in 100 μL of human whole blood. The procedure features an optimized clean-up step that combines protein precipitation-using a chilled acetonitrile/methanol mixture containing deuterated internal standards-with the direct removal of phospholipids via Phree™ tubes. This streamlined approach eliminates the need to transfer supernatants to separate vials. Analytes are separated using a liquid chromatography system and detected by high-resolution accurate-mass Orbitrap mass spectrometry with positive/negative polarity switching and parallel reaction monitoring acquisition mode, ensuring highly specific detection and sensitive quantification.
    Keywords:  Blood; Cannabinoids; Forensic toxicology; High-resolution mass spectrometry; Orbitrap; Parallel reaction monitoring
    DOI:  https://doi.org/10.1007/978-1-0716-5651-8_5
  35. Anal Chem. 2026 Nov 03. 98(43): 29925-29936
      Quantitative microbial metabolomics requires rapid quenching and highly standardized extraction, yet these pre-analytical steps remain labor-intensive and difficult to reproduce, limiting time-resolved intracellular measurements under controlled bioreactor cultivation. Here, we present an integrated robotic platform that couples parallel fermenter operation with circulation-based sampling, immediate cold-alcohol quenching, automated refrigerated centrifugation, interface-aware supernatant removal, and solvent extraction with controlled heating and mixing, followed by plate-based storage for liquid chromatography-tandem mass spectrometry (LC-MS/MS). To benchmark the precision of the automated preparation module, we compared repeated LC-MS/MS measurements of a single extract with measurements of independently processed samples subjected to post-quench automated harvesting, extraction, and transfer. The analysis was restricted to 76 analytes consistently detected in all replicates of both datasets. The mean coefficients of variation increased from 6.92% for repeated LC-MS/MS measurements to 8.82% for automated preparation, corresponding to a modest increase of 1.90 percentage points. These results indicate that post-quench automated preparation introduces a small but measurable additional source of variability while maintaining mean analytical variation below 10%. We then performed time-course endo- and exometabolomics across four widely used Escherichia coli lineages (BW25113, BL21(DE3), W, and C). Principal component analysis resolved strain-specific trajectories throughout batch growth and revealed strain-specific metabolic phenotypes, including coordinated accumulation of sugar phosphates and 2-C-methyl-d-erythritol 4-phosphate (MEP) pathway intermediates in strain C, and comparatively high intracellular pools of branched-chain amino acids in strain W. This platform enables standardized and traceable automated preparation for dense, time-resolved metabolomics and provides directly measurable phenotypes for host selection and metabolic engineering.
    DOI:  https://doi.org/10.1021/acs.analchem.6c01820
  36. Methods Mol Biol. 2027 ;3095 1-11
      Δ9-Tetrahydrocannabinol (THC) is the principal psychoactive cannabinoid in cannabis. Following consumption, it is metabolized in the liver to 11-hydroxy-Δ9-tetrahydrocannabinol, and subsequently to 11-nor-9-carboxy-Δ9-tetrahydrocannabinol, which are excreted in urine. The presence of THC and its metabolites in urine can serve as indicators of recent or past cannabis use. Here, a routine method for the simultaneous quantification of these three compounds is presented, using tandem enzymatic-alkaline hydrolysis, solid-phase extraction, and gas chromatography-mass spectrometry (GC-MS). The procedure is optimized for operational efficiency and analytical sensitivity and is routinely applied to urine samples submitted for cannabinoid testing in clinical and forensic toxicology.
    Keywords:  11-hydroxy-Δ9-tetrahydrocannabinol; 11-nor-9-carboxy-Δ9-tetrahydrocannabinol; GC–MS; Solid-phase extraction; Tandem hydrolysis; Urine; Δ9-tetrahydrocannabinol
    DOI:  https://doi.org/10.1007/978-1-0716-5651-8_1
  37. Methods Mol Biol. 2027 ;3095 147-160
      Novel synthetic opioids include various analogs of fentanyl and emerging nonfentanyl compounds with different chemical structures, such as AH-7921, MT-45, and U-47700. In recent years, these drugs have rapidly emerged on the drug market, and their abuse has been increasing worldwide. Furthermore, common drugs like heroin have been replaced or cut with fentanyl or new designer opioids, such as nitazenes. In this scenario, the detection of synthetic opioids in hair can provide insight into their current diffusion among the population and social characteristics of these synthetic drug users. Detection of new psychoactive substances and synthetic opioids is generally performed by means of targeted methods in mass spectrometry, as they generally provide adequate sensitivity and specificity. Additionally, new opportunities are offered by the nontargeted approaches allowed by modern UHPLC-HRMS instrumentation. In this chapter, we describe a simple, fast, specific, and sensitive UHPLC-MS/MS method able to detect 13 synthetic opioids (including fentanyl analogs) and metabolites in hair samples. Furthermore, the method includes the detection of 4-anilino-N-phenethyl-piperidine (4-ANPP), which is considered both a precursor and a metabolite of several fentanyl analogs. Also, we present a comprehensive and validated workflow that combines the use of UHPLC-QTOF-HRMS instrumentation with a simple hair sample extraction procedure for the detection of a variety of fentanyl analogs and metabolites.
    Keywords:  Fentanyl; Hair; NPS; QTOF; SWATH; Synthetic opioids; Untargeted
    DOI:  https://doi.org/10.1007/978-1-0716-5651-8_13
  38. Methods Mol Biol. 2027 ;3095 185-197
      Novel psychoactive substances, such as synthetic cathinones, are constantly evolving. Examples of recently reported substances within this class include eutylone, N,N-dimethylpentylone, N-propyl butylone, and pentylone. Given their occurrence in forensic casework, methods for toxicological analysis of these compounds are needed. The application of dried blood spots (DBS) to the analysis of traditional and novel stimulants provides multiple benefits such as low volume needed for sampling and facilitated transportation and storage. This chapter describes a fast and simple procedure for the simultaneous screening of traditional stimulants (amphetamine, methamphetamine, MDMA, MDA and cocaine) and synthetic cathinones (eutylone, N,N-dimethylpentylone, N-propyl butylone and pentylone) in DBS using liquid chromatography-tandem mass spectrometry (LC-MS/MS).
    Keywords:  Dried blood spots; Forensic toxicology; LC–MS/MS; Stimulants; Synthetic cathinones
    DOI:  https://doi.org/10.1007/978-1-0716-5651-8_16
  39. Methods Mol Biol. 2027 ;3095 27-33
      A sensitive and rapid method for the simultaneous determination of Δ9-tetrahydrocannabinol (THC), its hydroxylated metabolite (THCOH), and its carboxylated metabolite (THCCOOH) in whole blood and urine has been developed using solid-phase extraction (SPE) followed by gas chromatography-mass spectrometry (GC-MS). A microwave-assisted derivatization step was implemented to enhance analyte volatility and chromatographic performance, thereby improving detection sensitivity and reducing overall analysis time compared with conventional heating techniques. In this methodology, sample preparation is carried out by applying SPE to efficiently isolate the target cannabinoids from blood and urine matrices. Subsequent derivatization under microwave irradiation ensured complete conversion of the analytes to their more volatile derivatives, optimizing their separation and detection by GC-MS. The simplicity of the presented protocol, combined with the use of instrumentation accessible to most forensic toxicology laboratories, justifies its adoption in routine analyses.
    Keywords:  Blood; Cannabinoids; Drugs of abuse; GC–MS; Microwave-assisted derivatization; SPE; Urine
    DOI:  https://doi.org/10.1007/978-1-0716-5651-8_3
  40. J Am Soc Mass Spectrom. 2026 Nov 04. 37(11): 2712-2719
      The extracellular matrix (ECM) serves critical structural and functional purposes within tissues, but its spatial arrangement and composition across functional tissue units (FTUs) have not been fully elucidated. Here, we present a streamlined workflow for spatial matrisomics that enables confident identification of ECM peptides directly from tissue sections. By processing adjacent formalin-fixed, paraffin-embedded (FFPE) tissue sections in parallel, we generate MALDI-MSI-ready samples and matched LC-MS/MS data sets using a unified collagenase-based digestion strategy. This parallelized approach reduces sample handling and supports construction of a robust ECM peptide reference library. We further introduce an automated, open-source mass-matching pipeline that integrates LC-MS/MS peptide identifications with MALDI-MSI features to facilitate high-confidence annotation. Applying this workflow to human kidney tissues and pairing MSI data with AI-driven digital pathology, we resolve FTU-specific ECM profiles, including glomerular enrichment of Tenascin-C and Albumin, and tubular enrichment of COL1A2 and COL3A1 peptides. Across samples, we observe both conserved and variable ECM patterns, emphasizing the importance of spatially resolved analyses for understanding tissue ECM heterogeneity. Altogether, this approach advances spatial matrisomics by increasing throughput, reducing manual data curation, and enhancing confidence in ECM peptide identifications, which can enable future applications in studying fibrosis and kidney disease, for example.
    Keywords:  MALDI; fibrosis; mass spectrometry imaging; matrix-assisted Laser desorption/ionization; spatial proteomics
    DOI:  https://doi.org/10.1021/jasms.6c00180
  41. Front Cell Infect Microbiol. 2026 ;16 1934046
      Parasitic worms, helminths, cause significant morbidity and high infection rates globally. To understand parasite physiology and as basis for intervention strategies, knowledge on the parasite lipidome is a key component. High-resolution atmospheric pressure scanning microprobe MALDI MS imaging (AP-SMALDI MSI) enables spatially resolved molecular-level insights into biological samples. We applied this technique to study the lipidome of the common liver fluke Fasciola hepatica which causes fascioliasis in humans and grazing animals across all inhabited continents. In particular, four of the most relevant worm organs in terms of parasite-host contact and reproduction (tegument, intestine, ovary, and testis) were examined. We extracted m/z signals for each organ from AP-SMALDI MSI data of worm sections and the native sample surface, annotated them to lipid species using a database and eventually assigned 73% (positive-ion mode) and 61% (negative-ion mode) of the previously annotated signals to (bulk) lipid species by comparison with complementary LC-MS/MS data. Data revealed differences in the lipid constitution of the organs. Among other findings, we observed (Hex)Cer species exclusively present in the tegument and intestine, PS species to vary in abundance between dorsal and ventral tegument side, and PI lipids to occur with saturated C-chains in the tegument and with unsaturated ones in the gonads. High-resolution MSI also allowed for differentiation between intestinal ducts and gastrodermis and resolved several molecular layers in/around the ovary tissue. The comprehensive dataset comprises reproducibly detected lipid species and their distributions across the worm and offers a spatial lipidomic resource for investigators of F. hepatica and related species.
    Keywords:  AP-SMALDI; Fasciola hepatica; LC-MS/MS; MSI; fascioliasis; imaging; lipids; neglected tropical diseases (NTDs)
    DOI:  https://doi.org/10.3389/fcimb.2026.1934046
  42. MAbs. 2026 Dec;18(1): 2761105
      Native intact mass spectrometry (MS) is essential for resolving the structural heterogeneity of complex biotherapeutics. Traditionally, intact MS combines online chromatography (e.g. ion-exchange chromatography or size-exclusion chromatography). Here, we report an MS-centric, column-free direct infusion MS workflow that combines high-throughput off-line 96-well affinity purification with rapid and sensitive direct infusion MS. This approach achieves a sampling rate of ~1 min/sample with minimal sample consumption (<1 µL) and high sensitivity (detection of antibody drugs in the low µg/mL range). The method demonstrates excellent linearity (R2 ≥ 0.99) in the 1.953-500 µg/mL range, enabling relative quantitation and relative quality ranking across samples based on the deconvoluted MS signal. The utility of this direct infusion MS workflow is demonstrated through two case studies: 1) analysis of antibody-drug conjugate (ADC) stability and biotransformation in mouse serum, where direct infusion MS successfully tracked changes in drug-load distribution and average drug-to-antibody ratio; and 2) sensitive, high-throughput MS screening during early-stage bispecific antibody clone development. The workflow allows early detection of high-quality bsAb clones, providing results that show potential as an early indicator of drug quality in expanded fed-batch cultures. The serum stability study illustrates how this direct infusion MS workflow - despite being column free - can reveal critical product changes in highly complex sample matrices using a robust, rapid, and sensitive workflow. The established workflow uses commercially available instrumentation, reagents, and software, enabling easy implementation in biopharmaceutical analytical development and quality control laboratories.
    Keywords:  Antibody characterization; antibody-drug conjugate; clone screening; direct infusion mass spectrometry; drug-load distribution; drug-to-antibody ratio; serum stability
    DOI:  https://doi.org/10.1080/19420862.2026.2761105
  43. Ther Drug Monit. 2026 Nov 04.
       BACKGROUND/PURPOSE: Oxycodone is widely prescribed for moderate-to-severe pain, but is associated with a high risk of misuse and overdose. Global data indicate an increase in opioid-related hospitalizations and fatalities, highlighting the need for effective therapeutic drug monitoring (TDM). This review systematically evaluates the analytical approaches and biomonitoring of oxycodone in conventional and nonconventional matrices across clinical and medicolegal contexts.
    METHODS: A systematic search of PubMed and Scopus (2015-2026) identified studies reporting oxycodone detection, quantification, and pharmacokinetics in human biological matrices. Blood, plasma, urine, hair, oral fluid, meconium, and cerebrospinal fluid were collected. Data on sample preparation, analytical techniques, detection limits, and applications in therapeutic, forensic, and emergency settings were extracted.
    RESULTS: Plasma, whole blood, and urine were the primary matrices for oxycodone monitoring, with liquid chromatography-tandem mass spectrometry (LC-MS/MS) as the gold standard. Microsampling strategies including dried blood spots and volumetric absorptive microsampling, enable minimally invasive collection with reliable plasma correlations. Urine profiling supports the simultaneous assessment of parent drugs and metabolites, enabling the evaluation of CYP3A4 and CYP2D6 activity. Nonconventional matrices (hair, oral fluid, meconium, and cerebrospinal fluid) offer complementary information for chronic, recent, prenatal, and central nervous system exposure. Several LC-MS-based methods with validated analytical workflows and certified reference materials are currently available, providing comprehensive quantification of oxycodone and its metabolites across all matrices. These workflows often incorporate advanced extraction approaches, such as solid-phase extraction, liquid-liquid extraction, and electromembrane-based methods, which, combined with high-throughput LC-MS/MS, enhance sensitivity, specificity, and analytical sustainability. Limits of quantification across matrices range from 0.1 to 1 ng/mL, confirming the robustness of current TDM and forensic applications.
    CONCLUSIONS: Current evidence supports a shift toward faster analytical methodologies and the complementary use of alternative biological matrices for oxycodone biomonitoring. As no single specimen is suitable for every clinical or forensic application, matrix selection should be tailored to a specific interpretative context. Harmonization of interpretative criteria and integration with clinical, pharmacogenomic, and artificial intelligence-based approaches may further enhance oxycodone TDM.
    Keywords:  biomonitoring; conventional biological matrices; liquid chromatography–tandem mass spectrometry (LC-MS/MS); nonconventional biological matrices; oxycodone
    DOI:  https://doi.org/10.1097/FTD.0000000000001541
  44. Biomed Chromatogr. 2026 Dec;pii: e70652. [Epub ahead of print]40(12):
      Haplopine, a furoquinoline alkaloid with documented anti-inflammatory, antioxidant, and anti-atopic dermatitis properties, has not yet been characterized with respect to its in vivo disposition. Here, we developed a fast UPLC-MS/MS assay for quantifying haplopine in mouse blood. Aliquots of 20 μL of blood were subjected to acetonitrile-based protein precipitation and resolved on a BEH C18 column within a 4-min run. Quantification was performed in the positive-ion electrospray multiple reaction monitoring mode, monitoring the transitions m/z 246.2 → 231.3 for haplopine and m/z 326.2 → 291.4 for the internal standard. The method was linear over 1-1000 ng/mL (r2 = 0.9998), with intra- and inter-day precision below 13% and 11%, respectively; accuracy ranged from 90.2% to 110.8%, recovery exceeded 87.2%, and matrix effects were 92.8%-99.1%. The validated assay was then applied to study the pharmacokinetics of haplopine in mice following intravenous (2.0 mg/kg) and oral (8 and 16 mg/kg) administration. Absolute oral bioavailability reached 39.1% and 55.0% at 8 and 16 mg/kg, respectively, indicating moderate, dose-dependent systemic bioavailability. Collectively, these data constitute the first pharmacokinetic description of haplopine and provide a foundation for its continued development.
    Keywords:  UPLC‐MS/MS; bioavailability; haplopine; mouse blood; pharmacokinetics
    DOI:  https://doi.org/10.1002/bmc.70652
  45. Nucleic Acids Res. 2026 Nov 05. pii: gkag1127. [Epub ahead of print]
      The rapid growth of metabolomics data has increased the need for integrated storage, analysis, and reuse. Here, we present Metabolomics Subcenter (Met-SC) V1.0 (https://metabolomics.dicp.ac.cn/), an integrated database and platform for standardized data deposition, spectral-resource management, online analysis, and disease-focused knowledge mining. The deposition framework captures project, sample, pretreatment, and instrument metadata across chromatographic, capillary electrophoresis-mass spectrometry, and nuclear magnetic resonance workflows. Met-SC contains 7  756  867 reference spectra associated with 1 989 680 unique compounds and 73  014  049 unknown-feature spectra derived from diverse biological matrices and experimental conditions. Its web-based analysis module provides 27 functions for data preprocessing, quality-control visualization, and statistical analysis. Metabolism-centered knowledge graph for colorectal cancer (MetKG-CRC) comprises 108 679 biomolecular entities and 600 093 literature-supported evidence triples. By linking data deposition, spectral resources, analysis, and evidence-supported knowledge exploration in a single platform, Met-SC facilitates reproducible metabolomics data management and downstream discovery.
    DOI:  https://doi.org/10.1093/nar/gkag1127
  46. iScience. 2026 Nov 20. 29(11): 118012
      Lipids are central to membrane organization, signaling, myelination, and metabolic homeostasis in the central nervous system (CNS), where their abundance, turnover, and spatial distribution are tightly regulated. Stable isotope approaches provide complementary ways to interrogate this complexity. Here, we integrate evidence from cellular, animal, and human studies to compare stable isotope dilution (SID) and chemical isotope labeling (CIL) for precise lipid quantification with metabolic tracing strategies that resolve synthesis, turnover, pathway contribution, and lipid trafficking. We examine their implementation across mass spectrometry, NMR, vibrational spectroscopy (VS), and imaging platforms, together with kinetic and flux-modeling frameworks that connect isotope-enrichment patterns to pathway activity. We further highlight spatially and cell-type-resolved isotope measurements that extend lipid analysis from bulk abundance to regional and cellular metabolic organization. These advances establish a framework linking lipid composition with metabolic dynamics and provide mechanistic insight into CNS physiology, neurological disease, myelin repair, and metabolic intervention strategies.
    Keywords:  central nervous system; isotope tracing; lipid kinetics; lipid metabolism; stable isotopes
    DOI:  https://doi.org/10.1016/j.isci.2026.118012
  47. J Am Soc Mass Spectrom. 2026 Nov 04. 37(11): 2759-2767
      High-throughput quantitative proteomics across diverse biological conditions, including varying perturbations and temporal changes, is critical for elucidating disease mechanisms and treatment responses. Advances in mass spectrometry and isobaric labeling technologies have enabled powerful multiplexed analyses; however, commonly used methods rely on low-mass reporter ions that are prone to ratio distortion due to peptide co-isolation and co-fragmentation in complex samples. Complementary ion-based quantification offers an alternative approach by leveraging peptide-specific fragment ions generated at the MS2 level, enabling more accurate and interference-resistant measurements. Here, we present a novel 7-plex dimethylated leucine complementary ion (DiLeuC) isobaric labeling strategy for sensitive and accurate multiplexed proteomics. Through systematic optimization of higher-energy collisional dissociation (HCD) and high-field asymmetric waveform ion mobility spectrometry (FAIMS), we significantly improved complementary ion generation efficiency and proteome coverage. The DiLeuC platform demonstrated high quantitative accuracy and precision across both defined-ratio samples and a human-yeast dual-proteome model, effectively quantifying low-abundance species in the presence of a high-abundance background. Overall, DiLeuC provides a robust and sensitive solution for multiplexed proteomics, enabling accurate complementary ion-based quantification at the MS2 level without requiring SPS-MS3 acquisition. Its efficient complementary ion generation and strong resistance to interference make it well suited for complex biological samples and high-throughput proteomic applications.
    DOI:  https://doi.org/10.1021/jasms.6c00234
  48. J Sci Food Agric. 2026 Nov 05.
       BACKGROUND: Cereals are major staple foods, and seven newly registered herbicides have been permitted for cereal production in China. GB 2763-2026 set temporary maximum residue limits for these compounds, yet no official multi-residue detection method is available. This study aimed to develop and validate a modified acidified Quick, Easy, Cheap, Effective, Rugged and Safe liquid chromatography-tandem mass spectrometry (QuEChERS-LC-MS/MS) method for simultaneous determination of pinoxaden, monosulfuron-ester, pyribambenz-propyl, quintrione, pyraclonil, tripyrasulfone and tefuryltrione in wheat flour, brown rice and corn.
    RESULTS: Adding 10 mL L-1 formic acid into acetonitrile markedly improved the low recoveries of quintrione and tefuryltrione, raising recoveries from 52.1-62.3% to 88.6-91.5%. After optimizing hydration volume, vortex extraction time and primary secondary amine + C18 mixed sorbents, matrix effects were controlled within 0.81-1.19. Good linearities were obtained (r2 > 0.9945) over 5-100 μg L-1. Limits of detection ranged from 0.01 to 1.08 μg kg-1. Limits of quantification were 10 μg kg-1, defined as the lowest validated spiked level meeting SANTE/11312/2021 criteria. At three spiked levels (10, 20 and 100 μg kg-1), mean recoveries were 78.5-118.5% with relative SD values of 1.9-8.8%, complying with SANTE/11312/2021 criteria. Among 80 real cereal samples, only three samples contained trace herbicide residues far below national temporary maximum residue limits.
    CONCLUSION: The validated acidified QuEChERS-LC-MS/MS method is sensitive, rapid and reliable for monitoring seven herbicides in cereals. The formic acid-assisted extraction strategy provides a universal reference for multi-residue analysis of polar, easily-adsorbed pesticides in cereal matrices. © 2026 Society of Chemical Industry.
    Keywords:  LC‐MS/MS; acidified acetonitrile extraction; cereal herbicide residues; modified QuEChERS; multi‐residue analysis
    DOI:  https://doi.org/10.1002/jsfa.71226
  49. Anal Chem. 2026 Nov 03. 98(43): 29903-29913
      Identifying known compounds and elucidating unknown chemical structures from mass spectra remains a significant challenge due to the limited size of experimental reference libraries. Enhancing these libraries with predicted mass spectra through computational methods offers an opportunity to resolve unmatched spectra. In this paper, we present SPHERE-MS (Secondary-loss Powered Hybrid Edge Removal Engine for predicting Mass Spectra), a graph neural network model designed to predict mass spectra from molecular structures. The hybrid approach, combining bond-breaking and vocabulary-based strategies, enables SPHERE-MS to efficiently simulate multilevel fragmentation processes without the need to enumerate all possible bond combinations. Evaluations on the NIST-20, MSnLib, CASMI2022, and MassSpecGym data sets demonstrate that SPHERE-MS outperforms baseline models that rely on single fragment generation strategy, showing higher prediction accuracy and library retrieval success rates. Notably, SPHERE-MS also maintains reasonable accuracy even when applied to molecules with low structural similarity to the training set. This strong generalization capability makes SPHERE-MS a valuable tool for mass spectra prediction across large libraries, including those containing uncommon structures.
    DOI:  https://doi.org/10.1021/acs.analchem.6c01723
  50. Anal Bioanal Chem. 2026 Nov 04.
      Cyanobacteria are of global concern, impacting ecosystems and posing a public health risk from production of bioactive secondary metabolites, including several classes of potent mammalian toxins. Because of the thousands of possible metabolites, non-target analysis (NTA) using high-resolution mass spectrometry (HRMS) is of increasing interest for studying cyanobacteria. However, performance evaluation of these NTA methods is rarely considered, potentially raising concerns over the quality and validity of results. Here, a NTA workflow was developed for cyanobacterial metabolite profiling using data-dependent LC-HRMS/MS acquisition and semi-automated data processing, including product ion, mass list, and spectral library searching using metabolomics software. Rigorous method optimization and performance evaluation at each step were carried out based on detection of cyanotoxins in a multiclass cyanobacterial matrix reference material. Deeper profiling of this material further extended its utility for evaluation of NTA performance for metabolite classes beyond traditional cyanotoxins in the future. The workflow was applied to a set of environmental benthic cyanobacterial biofilm samples associated with recent animal deaths. This led to the detection of 116 secondary metabolites from microcystin, anatoxin, cyanopeptolin, anabaenopeptin, aeruginosin, and cyanobactin classes, greatly increasing reported compound diversity for benthic cyanobacteria, which have been poorly characterized compared to planktonic bloom-forming species. Because of the association of anatoxins in these samples with animal deaths, additional structural elucidation of two newly detected analogues was carried out via analytical scale semi-synthesis. The approaches presented are broadly applicable to class-based NTA in other fields where improved confidence in detection results is increasingly important.
    Keywords:   Microcoleus ; Anatoxins; Cyanopeptides; Cyanotoxins; LC–HRMS/MS; Reference materials
    DOI:  https://doi.org/10.1007/s00216-026-06890-8
  51. Bioanalysis. 2026 Nov 04. 1-17
      The continuous emergence of synthetic opioids, particularly fentanyl analogues and nitazenes, has created major analytical challenges for clinical and forensic toxicology. Alternative biological matrices have gained relevance as complementary specimens for opioid detection and quantification alongside conventional blood and urine. This review critically examines analytical advances reported between 2020 and 2026 for opioid determination in oral fluid, sweat, exhaled breath condensate, hair, meconium, vitreous humor, bile, pericardial fluid, nasal swab and teeth. Emphasis is placed on sample preparation strategies, miniaturized extraction approaches, chromatographic and mass spectrometric platforms, sensor-based methods and matrix-specific analytical performance. Oral fluid and hair remain the most established alternative matrices for assessing recent and retrospective exposure, respectively. Recent progress has involved improved sample preparation workflows, including microextraction by packed sorbent, fabric phase sorptive extraction, thin-film microextraction, dispersive micro-solid-phase extraction, supramolecular solvent extraction, cryogenic grinding and one-pot extraction strategies. Liquid Chromatography tandem mass spectrometry remains the predominant analytical platform, while high-resolution mass spectrometry-based approaches support broad screening, suspect analysis and retrospective data interrogation. Overall, alternative matrices are becoming increasingly valuable in opioid analysis, although methodological harmonization, matrix-specific interpretation and emerging synthetic opioids remain important challenges.
    Keywords:  Alternative biological matrices; Nitazenes; fentanyl analogues; opioid quantification; sample preparation; synthetic opioids
    DOI:  https://doi.org/10.1080/17576180.2026.2752807
  52. Food Res Int. 2026 Dec 01. pii: S0963-9969(26)02545-7. [Epub ahead of print]245(Pt 4): 120857
      Assessing the quality and authenticity of royal jelly (RJ) is essential due to its high nutritional and commercial value. In this study, Greek and Chinese RJ samples were analyzed using Liquid Chromatography coupled to Trapped Ion Mobility Spectrometry and High-Resolution Mass Spectrometry (LC-TIMS-HRMS) and compared for the first time to investigate their metabolomic profile. A total of 21 bioactive compounds from different classes were identified through target screening, while quantitative differences between the two were revealed. Chemometric evaluation contributed to the detection of characteristic compounds like quercetin, luteolin, and pinocembrin for the Greek geographical origin. In addition, the combination of non-target screening with chemometrics achieved 100% classification accuracy between Greek and Chinese samples and enabled the identification of additional discriminatory features, such as pentadecanoic acid, tetradecanoic acid, and oleic acid. Furthermore, non-target screening methodology was employed to assess the adulteration of Greek RJ with Chinese RJ, successfully detecting adulteration levels as low as 1%. Overall, the proposed LC-HRMS-based workflow can be an effective approach for the simultaneous authentication and detection of adulteration of RJ.
    Keywords:  Authenticity; Bee products; Geographical origin; Non-target screening; Target screening
    DOI:  https://doi.org/10.1016/j.foodres.2026.120857
  53. J Am Chem Soc. 2026 Nov 04. 148(43): 46615-46627
      Most small-molecule features detected in untargeted metabolomics remain unannotated, representing the dark matter of the metabolome. Here, we introduce MetaTag, a biochemical-reaction-guided framework that generates high-probability novel metabolites by combining abundant endogenous metabolites with common enzymatic transformations derived from KEGG pathways. In this proof-of-concept implementation, we focused on N-acylation and N-alkylation reactions. We synthesized and characterized a physical library of 1068 compounds, creating a public MS/MS database (https://mtdb-website.vercel.app). Screening against 27 rat tissues matched 180 previously unreported metabolites with 6 at level 1 (confirmed by RT, formula, MS/MS) and 174 at level 2 (confirmed by RT, formula). These metabolites exhibited tissue-specific distributions and participated in the interorgan exchange during fasting. Functional interrogation of one such metabolite, N-propionyltaurine, demonstrated its role as a redox-sensitive regulator in brown adipocytes. This biochemistry-guided strategy provides a scalable platform for the discovery of previously uncharacterized bioactive metabolites.
    DOI:  https://doi.org/10.1021/jacs.6c09579
  54. Methods Mol Biol. 2026 Nov 03.
      Platelet-rich plasma (PRP) is increasingly used in regenerative medicine, yet the lack of standardized procedures for its preparation, storage, and molecular characterization remains a critical bottleneck. This chapter provides a step-by-step laboratory protocol for the preparation of leukocyte-rich PRP (L-PRP) and pure PRP (P-PRP) from whole blood, followed by untargeted metabolomic analysis using liquid chromatography-quadrupole time-of-flight mass spectrometry (LC-QTOF-MS). The workflow includes blood collection, single-spin PRP fractionation, and methanol-based protein precipitation for metabolite extraction. The resulting extracts are subjected to chromatographic separation, high-resolution mass spectrometric detection, feature processing, and statistical analysis. Data evaluation includes principal component analysis (PCA), partial least squares discriminant analysis (PLS-DA), variable importance in projection (VIP) scoring, fold-change analysis, heatmap visualization, and putative metabolite annotation. To assess short-term storage, freshly processed aliquots are compared with matched aliquots stored at -20 °C for 7 days. The workflow enables characterization of formulation-dependent metabolic profiles and identification of differences between fresh and stored PRP. Collectively, these procedures provide a framework for PRP metabolomic profiling and may serve as a basis for the independent optimization and validation of alternative PRP preparation systems and targeted metabolomic assays.
    Keywords:  Chemometrics; Frozen Storage; Leukocyte-Rich PRP; Liquid Chromatography-Mass Spectrometry; Metabolomics; Platelet-Rich Plasma; Pure PRP
    DOI:  https://doi.org/10.1007/7651_2026_719